eddiTechnical Specifications

  1. Performance
  2. Electrical Specifications
  3. Mechanical Specifications

1. Performance

Power Control Technology varisineTM pure sine wave PWM (Pulse Width Modulation)
Outputs 2 (sequential operation with selectable priority)
Bypass Switch Integral On/Off/Bypass switch
Cooling Rear mounted passive cooled heatsink
Indicators LED indication: Supply On, Heater 1 and Heater 2 active
Display Graphical LCD with LED backlight (shows heating status and savings data)
PWM Resolution 0.1% (output voltage step size)
Measurement Accuracy +/- 1.5% (typical)
Power Conversion Efficiency 97.5% (typical)
Compliance LVD 2014/35/EU, EMC 2014/30/EU

EN60335-1:2012, EN55014-1:2006+A2:2011, EN55014-2:2015, EN61000-3-2:2014, EN61000-3-3:2013

Warranty 3 Years

 

2. Electrical Specifications

Rated Input Power 3.68kW
Rated Supply Voltage 230V AC Single Phase (+/- 10%)
Supply Frequency 50Hz / 60Hz
Rated Current 16A max. (determined by load)
Standby Power Consumption 3W
Generator Size Supported No limit (subject to 100A per-phase grid supply)
Heater Load Size 100W min. 3.68kW max.
Economy Tariff Sense Input 230V AC sensing (2.5kV isolated)
Wireless Interface 868 MHz (proprietary protocol) for wireless sensor and remote monitoring options
Grid Current Sensor 100A max. primary current, 16mm max. cable diameter
Supply Cable Entry Rear, bottom, or side option

 

3. Mechanical Specifications

Dimensions 220 x 205 x 87mm (excluding wall bracket)
Weight 4.3kg (excluding wall bracket)
Protection Degree IP20
Enclosure Material Painted Zintec steel
Operating Temperature -20°C to +40°C
Mounting Method Wall mounting bracket

 

Designed to permit installations compliant with IET Wiring Regulations BS7671 and the Electricity Safety, Quality, and Continuity Regulations 2002 and BS8300.