zappi v1Menus

  1. Main Menu
  2. Advanced Menu

2. Advanced Menu

Advanced Menu Options Description
Supply Grid Phase: Set the supply phase to use for this device – see Advanced Settings  for more information
Device Limit: Set the maximum available supply current to be drawn by the zappi – see Advanced Settings for more information
Export Margin: Minimum level of export power which is maintained when zappi is diverting surplus power – see Advanced Settings for more information
Grid Limit: Maximum grid import power limit. When charging, the charge power is reduced to keep import below this level. This also applies when boosting – see Advanced Settings for more information
Battery: Sets the mode for managing power when a battery system is present in the installation – see Battery Storage Systems for more information.
Net Phases: When set to ON will net the imports and exports across phases allowing surplus power from one phase to be used on a different phase. – see Advanced Settings for more information.
Linked Devices Devices Other myenergi devices can be wirelessly linked to zappi, this shows connected devices and their priorities. Settings for some devices are made here – see Linking Devices
Pairing Mode Puts this zappi in pairing mode so it can be linked to another device – see Linking Devices
Channel RF Channel Sets the radio frequency channel number used when linking other devices – see Linking Devices
Reset Settings Clear all linked device settings – see Linking Devices
CT Config CTINT Internal CT, used to configure a group limit – see see Linking Devices for details.
CT1: Set the function of CT1 input – see  see Linking Devices for more details.
CT2: Set the function of CT2 input – see CT Config for more details.
eSense Input Disabled eSense input is disabled
Boost If the eSense input is live, zappi will boost the charge – see eSense Input
Boost Timer Enable zappi will boost the charge if eSense is live AND the boost timer is set to operate at that time – see eSense Input
Compatibility PF Responsive: zappi will adapt to EV’s with poor power factor (e.g. Renault Zoe).
Min PWM: Control Pilot PWM minimum limit
Power Factor: When PF Responsive is ON, the measured power factor must be better than this set value to enable lower charging current set by Min PWM
End Charge Delay: Charge Complete status is delayed by this time to allow access to the vehicle without starting a new charge session
Infinite PWM: Keeps zappi ready to restart charge after charge is complete – this is needed on some EV’s when the user wants to preheat the vehicle in morning
Menu Passcode The code required to access the Advanced menu
System Restore Settings Erase Config Restore the configuration to factory default
Erase Data Clear all data from memory
Erase ALL Restore configuration to factory default and erase all data
Confirm Confirm restore options and re-boot device
Dowload Firmware Downloads latest firmware from hub
Bootloader Enter Bootloader mode